Electricity and Magnetism: Praxis Physical Science 5485
For Praxis Physical Science 5485, study charge interactions, electric fields, voltage, current, resistance, series and parallel circuits, power, and magnetic effects.
- Use the correct units and circuit relationships before calculating.
- Original examples below show how to distinguish charge from energy, compare circuit connections, and explain induction without confusing emf with current.
On this page11 sections
Charge, current and energy
Electric charge is a property of matter; electric current describes charge passing a location per unit time. Voltage describes an energy difference per unit charge, and resistance relates the voltage across a component to its current. These quantities answer different questions. Before calculating anything, identify whether the problem concerns an interaction between charges, a flowing current, an energy transfer or a magnetic effect. The same object can participate in more than one of these processes.
Use coulombs for charge, amperes for current, volts for potential difference and ohms for resistance. For example, 18 coulombs pass a point in six seconds. The average current is 18/6 = 3 amperes. This result describes a rate through that location. It does not mean that the wire contains only three coulombs or that three joules are transferred. Those conclusions would require different information. Writing the units beside every value keeps these distinctions visible.
Static charge and attraction
Like electric charges repel; unlike charges attract. Neutral means balanced net charge, not an absence of charged particles. An object can be attracted to a charged object while remaining neutral because its charge distribution shifts. Conductors permit relatively mobile charge; insulators restrict that movement. Friction and contact can transfer charge. Induction can leave an object charged without direct contact with the inducing object when an appropriate separation or grounding sequence is used.
Consider two conducting spheres. Two initially neutral conducting spheres touch while insulated from their surroundings. Bring a negatively charged object near the left sphere. Mobile electrons shift toward the right sphere. Separate the spheres while the object remains nearby, then remove it. The left sphere is now positive and the right sphere negative. The pair's total charge has not increased. If the spheres remain touching until after the nearby object is removed, that final separated-charge outcome does not follow.
This sequence tests a useful distinction: redistribution while objects remain connected is not the same as a permanent net charge on each separated object. Label the total system and track where electrons can move. Avoid describing positive charge in an ordinary metal as protons traveling through the wire. An attraction observation alone also cannot prove that the two objects have opposite net charges; one may be neutral and polarized.
Coulomb force and electric field
For the point-charge model, the force magnitude is F = k|q1q2|/r². Separation enters as a square, while each charge enters as a first power. The charge signs determine attraction or repulsion. An electric field describes the force per unit positive test charge at a location, E = F/q. Field direction is defined using that positive test charge, so a negative charge experiences force opposite to the field direction.
Start with a force of 0.80 newton. Keeping both charges unchanged and doubling their separation makes the force 0.80/4 = 0.20 newton. Doubling just one charge while keeping the original separation makes it 1.60 newtons. Doubling one charge and the separation together produces 1.60/4 = 0.40 newton. These are proportional calculations within the same point-charge model. They do not require inventing a value for either charge or substituting a rounded constant.
Read the requested result carefully. If the task asks for magnitude, report a positive value and specify attraction or repulsion separately. If several charges act on a target, their forces must be combined as vectors rather than automatically added as positive numbers. In a symmetrical original arrangement, equal positive charges placed equal distances left and right of a positive target exert opposite equal forces. The net force is zero even though neither individual force is zero.
Voltage is energy per charge
Potential difference has units of joules per coulomb. In a simple energy accounting model, the change in electric potential energy is q times the potential difference. Do not treat voltage as the number of charges moving per second. A battery can maintain a potential difference across an open circuit even when that circuit has no sustained conduction current. Completing a conducting path changes the situation, but the resulting current depends on the circuit.
Suppose 4 coulombs move through a potential difference of 9 volts. The associated energy magnitude is 4 × 9 = 36 joules. If 8 coulombs undergo the same change, the magnitude is 72 joules. The voltage remains 9 volts in both calculations. This example separates the energy available per unit charge from the total amount of charge involved. For a signed energy change, define the direction of motion and the reference potentials before assigning a sign.
Ohm’s law and its limits
For an ohmic component under the assumed conditions, V = IR. Rearrange it as I = V/R or R = V/I according to the unknown. A constant-resistance model makes current proportional to voltage. Not every component has a constant resistance over every operating condition: a nonlinear current-voltage relationship cannot be represented by one unchanged resistance merely because the letters V, I and R appear in the question.
Suppose an ideal resistor has resistance 8 ohms and a potential difference of 16 volts. Current is 16/8 = 2 amperes. If the same resistance is connected across 24 volts under the model assumptions, current is 3 amperes. If the voltage remains 16 volts but resistance becomes 32 ohms, current is 0.50 ampere. State which quantity was held constant. Otherwise, a claim that increasing resistance always changes current in a particular proportion can conceal a changing voltage.
Consider these measured pairs: 2 volts with 0.25 ampere, 4 volts with 0.50 ampere, and 6 volts with 0.75 ampere. Each ratio V/I is 8 ohms, consistent with the model across those measurements. A fourth pair, 8 volts with 0.80 ampere, gives 10 ohms. That observation calls for examining conditions or the model; it should not be rounded back to 8 simply to preserve the expected answer. Measurements describe the observed range, not all possible operating conditions.
Series circuits
In an ideal series resistor circuit, components share one path and carry the same current. Equivalent resistance is the sum of the resistances, while individual voltage drops add to the source voltage. Track connections rather than the visual arrangement of a drawing: two components next to each other are not necessarily in series. A junction offering separate conducting paths changes the circuit relationship.
A circuit places 4-ohm and 8-ohm resistors in series across an ideal 18-volt source. Total resistance is 12 ohms, giving current 18/12 = 1.5 amperes through both resistors. The drops are 1.5 × 4 = 6 volts and 1.5 × 8 = 12 volts. Their sum is 18 volts. A tempting incorrect answer gives each resistor all 18 volts. That would contradict the stated series connection and the sum of the drops.
Now replace the 8-ohm resistor with a 14-ohm resistor while keeping the ideal source at 18 volts. Total resistance becomes 18 ohms and current becomes 1 ampere. The 4-ohm resistor now has a 4-volt drop, even though that resistor itself did not change. Its behavior depends on the rest of the circuit. This is why identifying one familiar component is insufficient: calculate the equivalent network first, then work back to the component quantities.
Parallel circuits
Ideal parallel branches connect across the same two nodes and share the same potential difference. Branch currents add to the source current. For resistors, 1/Req = 1/R1 + 1/R2 + further reciprocal terms. Adding a conducting branch lowers the equivalent resistance below the previous value. This statement assumes the ideal circuit conditions, including a source that maintains the stated voltage.
Place 6-ohm and 12-ohm branches across an ideal 18-volt source. The branch currents are 3 amperes and 1.5 amperes. Source current is 4.5 amperes, so equivalent resistance is 18/4.5 = 4 ohms. Alternatively, 1/Req = 1/6 + 1/12 = 1/4. The 4-ohm result is below either branch resistance. An answer of 18 ohms would be the series sum and reveals that the topology was misread.
In a mixed network, put those parallel branches in series with another 5-ohm resistor. Replace the parallel group with its 4-ohm equivalent, giving 9 ohms overall. With an 18-volt ideal source, total current is 2 amperes. The series resistor drops 10 volts, leaving 8 volts across the parallel group. Branch currents are 8/6 and 8/12 amperes, whose sum is 2 amperes. Using 18 volts for each branch at this stage would ignore the voltage already dropped elsewhere.
Power and electrical energy
Electric power is the rate of energy transfer. For the simple steady circuit quantities used here, P = IV. For a resistor, substitution from Ohm’s law gives P = I²R or P = V²/R. Use the voltage across the relevant component, not automatically the source voltage. Energy equals power multiplied by elapsed time when power is constant. A kilowatt-hour is an energy unit, not a power rating.
In the series circuit above with current 1.5 amperes and resistances 4 and 8 ohms. Powers are 1.5² × 4 = 9 watts and 1.5² × 8 = 18 watts. Together they use 27 watts, equal to source power 18 volts × 1.5 amperes. The agreement is a consistency check. Calculating the first resistor as 18²/4 would give 81 watts because it incorrectly assigns the whole source voltage to that component.
For a separate energy exercise, an idealized device draws a steady 150 watts for four hours. Convert 150 watts to 0.150 kilowatt before multiplying: energy is 0.150 × 4 = 0.600 kilowatt-hour. Over five identical sessions, consumption is 3.00 kilowatt-hours. A fictional unit price of 20 cents per kilowatt-hour would give 60 cents for that consumption alone. This is not a current utility tariff or a total bill estimate. Standing charges and variable operating power are outside the assumed calculation.
Direct and alternating current
Direct current has one direction; its magnitude need not be perfectly constant. Alternating current reverses direction periodically. A graph with positive values that rise and fall can therefore still represent direct current. A graph crossing between positive and negative values represents a changing direction when the sign convention is fixed. Do not confuse a zero average over an AC cycle with zero energy transfer.
Suppose a graph shows current alternating between positive and negative values with a period of 0.020 second. Frequency is 1/0.020 = 50 cycles per second. A second graph rises and falls between 1 and 3 amperes without changing sign. The first alternates direction; the second does not. These are invented graph descriptions, not claims about a particular supply. For sinusoidal AC power questions, identify whether supplied values are peak or root-mean-square before using the relevant relationship.
Magnetic fields and electromagnets
Unlike magnetic poles attract and like poles repel. Magnetic field lines describe direction and relative field strength; they are a representation rather than physical threads. Outside a bar magnet, lines run from north toward south and continue through the magnet as closed loops. A current also produces a magnetic field. The field around an ideal straight wire circles it rather than following the wire in a straight line.
For a direction exercise, view a wire end-on with conventional current pointing toward you. Applying the right-hand rule gives counterclockwise field direction from that viewpoint. Reverse the current and the field direction reverses. If an answer says clockwise without defining the viewing direction, it is incomplete. Draw a dot or cross to indicate out of or into the page, then place the circular field arrow around the wire. Reversing the observer's viewpoint changes the description even when the physical field is unchanged.
Induction, motors and generators
A changing magnetic flux through a circuit induces an electromotive force. For a uniform field through a flat loop, flux is BA cos θ, with θ measured from the normal to the loop. Faraday’s law links average induced emf to the number of turns and the flux change per unit time. Lenz’s law sets the direction opposing the flux change. An open circuit can have induced emf without sustained conduction current.
Suppose a coil has 40 identical turns, loop area 0.030 square meter, and a uniform field perpendicular to the loop. The field increases from 0.20 to 0.50 tesla in 0.20 second. Flux change per turn is 0.030 × 0.30 = 0.009 weber. Average emf magnitude is 40 × 0.009/0.20 = 1.8 volts. If the identical change takes 0.40 second, magnitude falls to 0.90 volt. These values assume the stated field and geometry; they do not establish the coil's current without resistance and circuit information.
A motor converts electrical input into mechanical output through magnetic forces; a generator converts mechanical input into electrical output through induction. In a classification exercise, an externally turned coil connected to a load illustrates generation. A powered coil producing rotation illustrates motor action. Real devices can have additional energy transfers and losses. Classify the intended energy conversion first rather than deciding from the presence of a coil, which both descriptions include.
Common questions
Does voltage measure current?
No. Voltage is energy difference per unit charge; current is charge passing a location per unit time.
Must an attracted object have opposite net charge?
No. A charged object can attract a neutral object through polarization.
Do series resistors share the source voltage equally?
Only equal resistances have equal drops in the ideal series model. The current is shared; each drop is IR.
Is a kilowatt-hour a power unit?
No. It measures energy. A kilowatt measures power.
Does induced emf always produce current?
No. A sustained conduction current also needs an appropriate closed conducting path.