Acoustics and Psychoacoustics: Praxis Audiology 5343
Acoustics describes sound as a physical wave; psychoacoustics studies how people perceive it.
- Frequency relates to pitch, while intensity and pressure amplitude relate to physical energy and level.
- Decibel calculations are logarithmic, and a physical sound level is not the same as perceived loudness or audiometric hearing level.
On this page14 sections
- Start with the physical wave
- Frequency, pitch and harmonics
- Intensity and amplitude
- The logarithmic decibel scale
- Pressure level and intensity level
- Sound pressure level and hearing level
- Intensity, loudness and loudness growth
- Threshold and psychophysical measurement
- Apply the concepts without overclaiming
- A short calculation routine
- Frequency, wavelength and time
- Calculate an intensity-level difference
- Pressure amplitude and the square relationship
- What decibels do not tell you
Start with the physical wave
Sound is a pressure disturbance that travels through a medium. A periodic sound can be described by frequency, period, wavelength and propagation speed. Frequency is cycles per second, measured in hertz. Wavelength is the distance between repeating points in the wave. In a given medium, speed equals frequency times wavelength: v = fλ.
If sound speed is approximately 343 m/s and frequency is 1,000 Hz, wavelength is 343/1,000 = 0.343 m. At 4,000 Hz in the same medium, wavelength is about 0.086 m. Higher frequency means shorter wavelength when speed is fixed. The calculation describes a wave, not a clinical threshold.
Frequency, pitch and harmonics
Frequency is a measurable physical property. Pitch is the perceptual correlate of frequency, but perception depends on more than a single frequency. A complex periodic sound can contain a fundamental frequency and harmonics at integer multiples. The harmonic structure contributes to timbre and speech quality, while changes in fundamental frequency can contribute to perceived pitch.
Do not equate pitch with loudness. A sound can have the same frequency and different amplitude, or similar intensity with a different frequency. Speech contains changing spectra and time patterns; understanding it depends on audibility, frequency content, temporal cues, environment and listener factors. A question may ask you to distinguish the acoustic variable from the perceptual experience.
Intensity and amplitude
Sound intensity is power transferred per unit area, measured in watts per square metre. For a sound wave in a given medium, intensity is proportional to the square of pressure amplitude. Doubling pressure amplitude therefore produces four times the intensity, assuming the other conditions in the relationship remain fixed.
This squared relationship matters in decibel problems. If pressure amplitude changes by a factor of ten, intensity changes by a factor of one hundred. A common mistake is to apply the intensity formula directly to an amplitude ratio. Identify whether the question gives intensity or pressure before selecting a logarithmic equation.
The logarithmic decibel scale
OpenStax presents sound intensity level as β = 10 log10(I/I0), where I0 is a reference intensity. A ratio of 10 gives 10 dB; a ratio of 100 gives 20 dB; a ratio of 1,000 gives 30 dB. Because the scale is logarithmic, equal decibel steps represent multiplicative changes in intensity.
Worked example: sound B has 40 times the intensity of sound A. The difference is 10 log10(40), about 16.0 dB. If the ratio is 0.01, then 10 log10(0.01) = -20 dB relative to the reference. A negative difference means the compared intensity is lower; it does not mean the sound has negative physical energy.
Pressure level and intensity level
When a problem uses sound-pressure amplitude rather than intensity, the corresponding level relation uses 20 log10 of the pressure ratio under the same acoustic reference conditions. This follows from intensity being proportional to pressure squared: 10 log10(p2²/p1²) equals 20 log10(p2/p1). Keep the stated quantity and reference consistent.
For example, doubling pressure amplitude corresponds to 20 log10(2), about 6.02 dB. The intensity ratio is four, and 10 log10(4) produces the same result. This is a useful cross-check. Do not use a 20-log formula on an intensity ratio or mix values referenced to different systems.
Sound pressure level and hearing level
Sound pressure level describes a physical pressure relative to a specified acoustic reference. Audiometric dB HL is a calibrated hearing-level scale tied to frequency-specific reference thresholds for the transducer and measurement conditions. The numeric labels may both use decibels, but they answer different measurement questions. A 20 dB HL audiometric result is not automatically equivalent to a 20 dB SPL sound in the room.
A threshold recorded in dB HL depends on the audiometer, transducer, calibration and test procedure. Do not convert between SPL and HL by subtracting a single universal offset. A clinical question must state the relevant reference or calibration. If it does not, explain which distinction is needed rather than inventing a conversion.
Intensity, loudness and loudness growth
Loudness is a perceptual judgment, not a physical unit that can be read directly from intensity. Perceived loudness can depend on frequency, level, duration, bandwidth, context and the listener. Equal physical intensity does not guarantee equal perceived loudness across frequency. Psychoacoustics studies relationships among stimuli, responses and perception.
A 10 dB increase corresponds to a tenfold intensity ratio, but it does not mean every listener perceives a fixed tenfold loudness increase. Avoid shortcut claims such as “10 dB always sounds twice as loud” unless a source and specific conditions support them. The exam may test the difference between a physical ratio and a subjective response.
Threshold and psychophysical measurement
A threshold is defined by the measurement task and response method. In pure-tone behavioral audiometry, ASHA describes a threshold as the lowest intensity at which a frequency is perceived 50 percent of the time under the procedure. It is an operational result with repeatability and patient factors, not an absolute boundary independent of method.
Psychometric methods examine how responses vary as stimuli change. Reliability asks whether a procedure yields consistent results under appropriate repeated conditions; validity asks whether it measures what it is intended to measure. Calibration supports accurate equipment output. These ideas are related but not interchangeable: a well-calibrated device does not guarantee a reliable response or a valid interpretation.
Apply the concepts without overclaiming
For a fictional screening room, a meter records a higher sound level after a ventilation fan is switched on. The physical measurement documents environmental sound under the measurement setup. It does not by itself show the child’s hearing threshold or establish that a specific test result is invalid. The program should compare conditions with applicable standards and protocol.
For a frequency case, a tone at 500 Hz has a lower frequency than one at 2,000 Hz and a longer wavelength in the same medium. For a ratio case, calculate level from the stated physical variable. For a patient case, distinguish measurement from perception and from clinical interpretation. This three-part separation prevents common concept errors.
A short calculation routine
First identify the measured quantity: intensity, pressure amplitude, frequency or wavelength. Second write the relevant relationship. Third substitute values with units and keep the reference clear. Fourth interpret the result in words. For v=fλ, solve for the requested variable. For intensity level, use 10 log10 of the intensity ratio. For pressure level, use the pressure ratio relation.
Estimate before calculating. A tenfold intensity increase should produce 10 dB, while a hundredfold increase should produce 20 dB. If the answer is 100 dB for a ratio of 100, check whether the logarithm or multiplier was misapplied. Explain the physical meaning and avoid extending the answer into an unsupported loudness or hearing-loss conclusion.
Frequency, wavelength and time
Frequency is cycles per second; period is the time for one cycle, so T = 1/f. At 500 Hz the period is 0.002 seconds, or 2 milliseconds. With sound speed held near 343 m/s, wavelength is 343/500 = 0.686 m. A higher frequency in the same medium has a shorter wavelength.
These relationships help separate temporal and spectral descriptions. A change in frequency changes pitch perception, while a change in amplitude changes signal strength. Complex sound can include a fundamental and harmonics. Speech moves through time and frequency, so its intelligibility cannot be reduced to one frequency or intensity number.
Calculate an intensity-level difference
Use the ratio directly. If sound A has intensity 2 units and sound B has 18 units under the same conditions, the ratio B/A is 9. The intensity-level difference is 10 log10(9), approximately 9.54 dB. The values “units” cancel because the formula uses a ratio.
Always specify the comparison direction. If B is weaker than A, the ratio is below one and the computed level difference is negative relative to A. This does not mean absolute sound intensity is negative. A signed difference describes which reference is larger.
Pressure amplitude and the square relationship
If pressure amplitude is tripled in the same medium, intensity becomes nine times as large because intensity is proportional to pressure squared. The corresponding level change is 10 log10(9), about 9.54 dB, or equivalently 20 log10(3). This agreement is a useful check on the two formulas.
Do not confuse amplitude with intensity in a graph or word problem. Intensity is proportional to amplitude squared, not directly to amplitude. A doubling of pressure is a fourfold intensity ratio and about a 6 dB level change. A doubling of intensity is about a 3 dB change.
What decibels do not tell you
A decibel value needs a reference and measured quantity. dB SPL refers to sound pressure relative to an acoustic reference. dB HL uses audiometric reference thresholds and equipment calibration. Sound intensity level is another physical description. Without the reference, a bare “dB” number can be ambiguous.
Decibels do not by themselves describe the listener’s communication success, loudness discomfort or diagnosis. Perception depends on frequency, duration, context and person. In an exam response, name the physical quantity and reference before drawing a perceptual or clinical conclusion.
Common questions
What is the difference between frequency and pitch?
Frequency is a physical wave property; pitch is a perception related to frequency.
What does a 10 dB intensity-level increase mean?
It corresponds to a tenfold intensity ratio under the same reference conditions.
Are dB SPL and dB HL the same?
No. SPL is a physical sound-pressure level; HL is calibrated to audiometric reference thresholds.