GROL electrical questions test voltage, current, resistance and power, then extend those relationships to AC circuits.

  • Start with units and a circuit model.
  • Ohm’s law applies directly to a resistor; AC problems may also require reactance, impedance and phase.
On this page8 sections
  1. Start with the quantities
  2. Calculate current and power
  3. Solve a series circuit
  4. Solve a parallel circuit
  5. Use Kirchhoff’s laws
  6. Move from DC to AC
  7. Reactance and impedance
  8. Check a calculation

Start with the quantities

Voltage is a difference in electric potential between two points. Current is the rate at which charge flows. Resistance describes how strongly a component opposes current. Power is the rate at which energy is transferred or converted. Write the quantity the question asks for, including its unit, before choosing an equation.

The common units are volts, amperes, ohms and watts. Prefixes change their size: 1 milliampere is 0.001 ampere, 1 kilohm is 1,000 ohms and 1 megohm is 1,000,000 ohms. Convert prefixes before calculating. A result can look plausible while being wrong by a factor of 1,000.

For a resistive circuit, Ohm’s law is V = IR. Rearrange it to I = V/R or R = V/I. The relationship also predicts changes. At constant resistance, doubling voltage doubles current. At constant voltage, doubling resistance halves current. These comparisons can eliminate answers before arithmetic is needed.

Calculate current and power

Suppose a 600 ohm resistor has 12 volts across it. Current is 12/600 = 0.02 amperes, or 20 milliamperes. Power is VI = 12 × 0.02 = 0.24 watts. The equivalent expression V²/R gives 144/600 = 0.24 watts. Both calculations describe the same resistor.

A resistor rated at exactly 0.24 watts would have no allowance above that calculated dissipation. Practical selection also considers tolerance, temperature and operating conditions. For a question asking only for dissipated power, the answer remains 0.24 watts. Do not substitute a guessed component rating for the requested quantity.

The other useful expression is P = I²R. Notice the square: doubling current through an unchanged resistor makes dissipation four times as large. This explains why a relatively small increase in current can produce a much larger heating effect.

Solve a series circuit

In a series path, the same current flows through every component. Resistances add. Voltage divides among resistors in proportion to their resistance. The sum of the voltage drops equals the source voltage in a simple closed loop.

Consider 200 ohms and 400 ohms in series across 12 volts. Total resistance is 600 ohms and current is 20 milliamperes. The drops are 0.02 × 200 = 4 volts and 0.02 × 400 = 8 volts. They add to 12 volts, providing a useful check.

Giving both resistors the full 12 volts would describe parallel branches. Trace the wires before calculating. Components drawn next to each other are not necessarily in series; electrical connections determine the relationship.

An open component in a simple series circuit interrupts the whole path, making current zero. A shorted resistor can reduce total resistance and increase current through the remaining components. Predict the change from the path rather than assuming every failed component stops the circuit.

Solve a parallel circuit

Parallel branches share the same voltage, and their currents add at the supply. For resistors, 1/Rtotal = 1/R1 + 1/R2 + further branch terms. For two resistors, Rtotal = R1R2/(R1 + R2).

Two 600 ohm resistors in parallel give 300 ohms. Across 12 volts, each draws 20 milliamperes and the source supplies 40 milliamperes. Total power is 12 × 0.04 = 0.48 watts, equal to the sum of the two branch dissipations.

The equivalent resistance of positive resistors in parallel is smaller than the smallest branch resistance. An answer of 1,200 ohms for two 600 ohm parallel resistors has used the series rule.

For a mixed network, reduce only components that genuinely share a series path or the same pair of nodes. Redraw the simpler circuit after each reduction. This preserves which voltage belongs across which part of the network.

Use Kirchhoff’s laws

Kirchhoff’s current law says current entering a node equals current leaving it. If 50 milliamperes enters and one of two outgoing branches carries 18 milliamperes, the other carries 32 milliamperes.

Kirchhoff’s voltage law says the algebraic sum of voltage changes around a closed loop is zero. A 12 volt rise and drops of 4 volts and 8 volts balance. Use consistent signs: crossing a source from negative to positive is a rise; crossing a resistor in the direction of current is a drop.

These laws help when a network cannot immediately be reduced. They also help interpret measurements. Two readings taken against different reference points cannot casually be added as though they were drops along the same loop.

Move from DC to AC

Frequency is cycles per second. Period is time per cycle, so T = 1/f. A 1 kilohertz signal has a period of 1 millisecond. A 1 megahertz signal has a period of 1 microsecond. Convert frequency to hertz before calculating period in seconds.

For a sine wave, RMS voltage is peak voltage divided by √2, approximately 0.707 times peak. Peak-to-peak voltage is twice peak for a sine wave centered on zero. A 10 volt peak sine wave is about 7.07 volts RMS and 20 volts peak to peak.

RMS describes equivalent heating effect in a resistor. The sine-wave factor is not universal. Square waves, pulse trains and signals with DC offset can have different peak-to-RMS relationships. Identify the waveform rather than applying 0.707 automatically.

A resistive AC load has current and voltage in phase. Reactive components introduce phase differences. Average power therefore depends on more than simply multiplying any two voltage and current readings. For sinusoidal quantities, real power is Vrms × Irms × power factor.

Reactance and impedance

An inductor opposes changes in current. Its reactance is XL = 2πfL, so it increases with frequency. A capacitor stores charge and opposes changes in voltage. Its reactance is XC = 1/(2πfC), so it decreases with frequency.

At 1 kilohertz, a 10 microfarad capacitor has about 15.9 ohms of reactance. At 10 kilohertz, the same ideal capacitor has about 1.59 ohms. A tenfold frequency increase produces a tenfold decrease in capacitive reactance.

Impedance combines resistance and reactance. In a series circuit with resistance R and net reactance X, magnitude is √(R² + X²). A 30 ohm resistance and 40 ohm reactance give 50 ohms of impedance, not 70. The components have a phase relationship and do not add like ordinary scalar resistances.

In a series LC circuit, resonance occurs when inductive and capacitive reactances are equal. The ideal resonant frequency is 1/(2π√LC). Net series reactance cancels, but resistance and losses remain. Resonance does not make every voltage or current zero.

Check a calculation

Identify DC or AC conditions, the network arrangement and the requested quantity. List known values in base units. Calculate, then convert the result into the unit used in the choices. Avoid rounding every intermediate step.

Finally, compare the result with the expected trend. Adding a parallel resistive branch increases source current at fixed voltage. Increasing frequency reduces ideal capacitive reactance. If the answer contradicts the trend, reconsider the model before choosing a response.

Common questions

Which formulas come first?

Learn V = IR and P = VI, then P = I²R and P = V²/R. Add series and parallel resistance, T = 1/f, and the reactance equations.

Is current the same throughout a circuit?

It is the same along a simple series path. At a junction it divides, and the outgoing branch currents add to the incoming current.

Can I add resistance and reactance directly?

Not generally. In a simple series R-X circuit, impedance magnitude is √(R² + X²).

Why does RMS matter?

It relates an AC waveform to equivalent heating in a resistor. The 0.707 peak-to-RMS factor applies to a sine wave.