The twelve categories

Concrete

Compiled by the Sitonce editorial team from the PSI Candidate Information Bulletin, NASCLA's own published material and the federal standards named belowUpdated 2 min readFacts verified 4 September 2026
The short answer

Six of 115 scored questions covering formwork and shoring, reinforcing steel placement and cover, mixing and placing, and curing and weather concreting. The safety provisions overlap with General Requirements.

Six questions. Worth preparing properly because the numbers are specific and lookup-friendly.

The four subtopics

  • Formwork, shoring and reshoring
  • Reinforcing steel - placement, cover and splices
  • Mixing, placing, consolidation and joints
  • Curing, testing and cold and hot weather concreting

The numbers

ItemFigure
Standard test age28 days
Common specified strength3,000 pounds per square inch
Cover against earth3 inches
Cover, formed and exposed to weather2 inches with larger bars
Cold weather threshold40 degrees Fahrenheit
Hot weather threshold90 degrees Fahrenheit
Common minimum moist curing7 days

Learn cover as a pair. Three inches against earth, two inches formed and exposed - the difference is whether concrete was cast directly against the ground.

Rebar impalement is a safety question

Protruding reinforcing steel must be guarded to eliminate the impalement hazard, under 29 CFR 1926.701(b). It sits in the concrete category and the answer is in the OSHA standards, which is exactly the kind of cross-reference that costs time if you have not thought about it.

Formwork removal

Only when the concrete has gained sufficient strength, determined under a plan prepared by a qualified person, at 29 CFR 1926.703(e).

Note qualified rather than competent. The distinction is tested.

The slump test

Measures workability, not strength. Candidates who half-remember it as a strength test lose the question, and it is asked.

Common questions

How many concrete questions are on the NASCLA exam?

6 of the 115 scored questions.

At what age is concrete strength tested?

28 days is the standard age for compressive strength testing.

What concrete cover is required against earth?

3 inches where cast against and permanently exposed to earth, and 2 inches for formed surfaces exposed to weather with larger bars.

What does the slump test measure?

Workability, not strength.

When may formwork be removed?

When the concrete has gained sufficient strength, determined under a plan by a qualified person, at 29 CFR 1926.703(e).